{"id":6142,"date":"2023-04-16T10:45:24","date_gmt":"2023-04-16T10:45:24","guid":{"rendered":"https:\/\/er-c.org\/?page_id=6142"},"modified":"2023-10-05T11:00:32","modified_gmt":"2023-10-05T11:00:32","slug":"tfs-aquilos-2-cryo-fib","status":"publish","type":"page","link":"https:\/\/er-c.org\/index.php\/facilities-2\/life-science\/cryo-electron-microscopy-facility\/cryo-em-instrumentation\/cryo-em-microscopes\/tfs-aquilos-2-cryo-fib\/","title":{"rendered":"TFS Aquilos 2 Cryo-FIB"},"content":{"rendered":"\n<h1 class=\"wp-block-heading\">TFS Aquilos 2 Cryo-FIB  <\/h1>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"6145\" src=\"https:\/\/er-c.org\/wp-content\/uploads\/2023\/04\/Aquilos-1-1024x768.png\" alt=\"\" class=\"wp-image-6145\" srcset=\"https:\/\/er-c.org\/wp-content\/uploads\/2023\/04\/Aquilos-1-1024x768.png 1024w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/04\/Aquilos-1-300x225.png 300w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/04\/Aquilos-1-768x576.png 768w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/04\/Aquilos-1.png 1341w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"6149\" src=\"https:\/\/er-c.org\/wp-content\/uploads\/2023\/04\/Aquilos-2-2-1024x768.png\" alt=\"\" class=\"wp-image-6149\" srcset=\"https:\/\/er-c.org\/wp-content\/uploads\/2023\/04\/Aquilos-2-2-1024x768.png 1024w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/04\/Aquilos-2-2-300x225.png 300w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/04\/Aquilos-2-2-768x576.png 768w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/04\/Aquilos-2-2-1536x1152.png 1536w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/04\/Aquilos-2-2-2048x1536.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<figcaption class=\"blocks-gallery-caption wp-element-caption\">Left: Operater and technician (Dr. Sabrina Berkamp and Pia Sundermeyer) at the Aquilos 2, right: Image of a human RPE1 cells as viewed in Aquilos 2 system under laser, ion and scanning electron microscope beam during different stages of milling (image credit: Dr. Olivera Korculanin)<\/figcaption><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-headline so-widget-sow-headline-default-f8d66e93cdeb\"\n\t\t\t\n\t\t><div class=\"sow-headline-container \">\n\t\t\t\t\t\t<div class=\"decoration\">\n\t\t\t\t\t\t<div class=\"decoration-inside\"><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n<\/div>\n\n\n<h2>Typical applications<\/h2>\n<p>The Aquilos 2 is a dual beam FIB-SEM platform specifically designed for sectioning of cryo-fixed samples, producing thin lamellae suitable for cryo-electron tomography at an TEM in an automated batch method. Updated with the integrated fluorescence microscopy module &#8211; METEOR system and CERES ice shield (Delmic), our Aquilos 2 allows for performing <em>in-situ<\/em> fluorescence microscopy directly on the sample inside the system and reduces transfer steps and associated ice contamination, simultaneously increasing the efficiency of the cryo- correlative light and electron microscopy (CLEM) pipeline. The Aquilos 2 can be used to cut \u201cwindows\u201d in (biological specimen) so cellular processes can be subsequently visualized and later resolved three-dimensionally in their native environment.<\/p>\n\n\n<div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-headline so-widget-sow-headline-default-f8d66e93cdeb\"\n\t\t\t\n\t\t><div class=\"sow-headline-container \">\n\t\t\t\t\t\t<div class=\"decoration\">\n\t\t\t\t\t\t<div class=\"decoration-inside\"><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n<\/div>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<figure class=\"wp-block-table\">\n<h2>Technical specifications<\/h2>\n<table style=\"width: 100%; height: 443px; margin: 0px;\">\n<tbody>\n<tr style=\"height: 23px;\">\n<td style=\"border-style: solid; border-color: #ebebeb; width: 20%; height: 23px;\" scope=\"row\">Operating voltage<\/td>\n<td style=\"border-style: solid; border-color: #ebebeb; width: 80%; height: 23px;\" scope=\"row\">Field Emission gun with operation voltage range of 200 V to 30 kV<\/td>\n<\/tr>\n<tr style=\"height: 46px;\">\n<td style=\"border-style: solid; border-color: #ebebeb; width: 20%; height: 46px;\" scope=\"row\">Resolution of optics<\/td>\n<td style=\"border-style: solid; border-color: #ebebeb; width: 80%; height: 46px;\" scope=\"row\">7 nm at 30 kV<\/td>\n<\/tr>\n<tr style=\"height: 46px;\">\n<td style=\"border-style: solid; border-color: #ebebeb; width: 20%; height: 46px;\" scope=\"row\">Operating conditions<\/td>\n<td style=\"border-style: solid; border-color: #ebebeb; width: 80%; height: 46px;\" scope=\"row\">Cryo \/ liquid nitrogen conditions<\/td>\n<\/tr>\n<tr style=\"height: 119px;\">\n<td style=\"border-style: solid; border-color: #ebebeb; width: 20%; height: 119px;\" scope=\"row\">Features<\/td>\n<td style=\"border-style: solid; border-color: #ebebeb; width: 80%; height: 119px;\" scope=\"row\">Automated batch cryo-lamella milling (AutoTEM TFS) <br \/>EasyLift<sup>TM <\/sup>Cryo <br \/>METEOR Fluorescence module <br \/>Ceres Ice shield <br \/>Slice and view<\/td>\n<\/tr>\n<tr style=\"height: 70px;\">\n<td style=\"border-style: solid; border-color: #ebebeb; width: 20%; height: 70px;\" scope=\"row\">Detectors<\/td>\n<td style=\"border-style: solid; border-color: #ebebeb; width: 80%; height: 70px;\" scope=\"row\">Everhardt-Thornley external SE detector (ETD) <br \/>In-Lens Detection System <br \/>METEOR<\/td>\n<\/tr>\n<tr style=\"height: 46px;\">\n<td style=\"border-style: solid; border-color: #ebebeb; width: 20%; height: 46px;\" scope=\"row\">Stage<\/td>\n<td style=\"border-style: solid; border-color: #ebebeb; width: 80%; height: 46px;\" scope=\"row\">Fully rotatable (360\u00b0) cryo-stage (&lt;-170\u00b0) with Auto-grid pre-tilted shuttle and a tilt range of -15\u00b0 to +55\u00b0<\/td>\n<\/tr>\n<tr style=\"height: 93px;\">\n<td style=\"border-style: solid; border-color: #ebebeb; width: 20%; height: 93px;\" scope=\"row\">Software<\/td>\n<td style=\"border-style: solid; border-color: #ebebeb; width: 80%; height: 93px;\" scope=\"row\">Maps including image correlation and lamella preparation functions <br \/>Auto-TEM for milling automation <br \/>Auto Slice &amp; View for 3D volume imaging <br \/>Odemis fluorescence software (Delmic)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The Aquilos 2 is a dual beam FIB-SEM platform specifically designed for sectioning of cryo-fixed samples, producing thin lamellae suitable for cryo-electron tomography at an TEM in an automated batch method. Updated with the integrated fluorescence microscopy module &#8211; METEOR system and CERES ice shield (Delmic), our Aquilos 2 allows for performing in-situ fluorescence microscopy directly on the sample inside the system and reduces transfer steps and associated ice contamination, simultaneously increasing the efficiency of the cryo- correlative light and electron microscopy (CLEM) pipeline. The Aquilos 2 can be used to cut \u201cwindows\u201d in (biological specimen) so cellular processes can be subsequently visualized and later resolved three-dimensionally in their native environment.<\/p>\n","protected":false},"author":2,"featured_media":6145,"parent":6072,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/pagebuilder.php","meta":{"_themeisle_gutenberg_block_has_review":false,"footnotes":""},"class_list":["post-6142","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/6142","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/comments?post=6142"}],"version-history":[{"count":15,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/6142\/revisions"}],"predecessor-version":[{"id":7485,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/6142\/revisions\/7485"}],"up":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/6072"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/media\/6145"}],"wp:attachment":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/media?parent=6142"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}