{"id":6133,"date":"2023-04-16T10:17:31","date_gmt":"2023-04-16T10:17:31","guid":{"rendered":"https:\/\/er-c.org\/?page_id=6133"},"modified":"2023-10-05T11:00:04","modified_gmt":"2023-10-05T11:00:04","slug":"tfs-titan-krios-g4","status":"publish","type":"page","link":"https:\/\/er-c.org\/index.php\/facilities-2\/life-science\/cryo-electron-microscopy-facility\/cryo-em-instrumentation\/cryo-em-microscopes\/tfs-titan-krios-g4\/","title":{"rendered":"TFS Titan Krios G4"},"content":{"rendered":"\n<h1 class=\"wp-block-heading\">TFS Titan Krios G4  <\/h1>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"263\" data-id=\"6892\" src=\"https:\/\/er-c.org\/wp-content\/uploads\/2023\/05\/Krios-neu-1024x263.png\" alt=\"\" class=\"wp-image-6892\" srcset=\"https:\/\/er-c.org\/wp-content\/uploads\/2023\/05\/Krios-neu-1024x263.png 1024w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/05\/Krios-neu-300x77.png 300w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/05\/Krios-neu-768x197.png 768w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/05\/Krios-neu-1536x395.png 1536w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/05\/Krios-neu-2048x526.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<figcaption class=\"blocks-gallery-caption wp-element-caption\">A and B) Operator and user (Dr. Thomas Heidler and Aikaterini Filopoulou) at the Titan Krios 300 kV C). Micrograph of a vitrified tobacco mosaic virus (TMV) as viewed at 96 kX nominal magnification in Titan Krios 300 kV (picture credit: Dr. Olivera Korculanin)<\/figcaption><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-headline so-widget-sow-headline-default-f8d66e93cdeb\"\n\t\t\t\n\t\t><div class=\"sow-headline-container \">\n\t\t\t\t\t\t<div class=\"decoration\">\n\t\t\t\t\t\t<div class=\"decoration-inside\"><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n<\/div>\n\n\n<h2>Typical applications<\/h2>\n<p>The Krios G4 (Thermo-Fisher Scientific) is a 300 kV FEG cryo-electron microscope with X-FEG field emitter and a three-lens condenser system. The detector options are a Gatan BioContinuum energy filter mounted K3 direct electron detection camera and a bottom mounted Falcon 4(i) detector (FEI). Combined with fringe-free imaging (FFI) and aberration-free image shift (AFIS) in EPU, high-throughput imaging rates can be achieved. The microscope can be tuned set up for single-particle imaging, STEM and tomography experiments. Additionally, the Titan Krios is equipped with a Panther detector system (4 segments and annular dark-field detectors) that can be used for iDPC and HAADF-STEM imaging. The acquisition rate for a single particle sample on the Titan Krios is ~250-700 acquisitions\/hour and we have achieved a maximal resolution of 1.7 \u00c5 with an apo-ferritin test sample.<\/p>\n\n\n<div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-headline so-widget-sow-headline-default-f8d66e93cdeb\"\n\t\t\t\n\t\t><div class=\"sow-headline-container \">\n\t\t\t\t\t\t<div class=\"decoration\">\n\t\t\t\t\t\t<div class=\"decoration-inside\"><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n<\/div>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h2>Technical specifications<\/h2>\n<table style=\"border-collapse: collapse; width: 100%; height: 465px; margin: 0px;\">\n<tbody>\n<tr style=\"height: 46px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"border-style: solid; border-color: #ebebeb; width: 20%; height: 46px;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">Operating voltage<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"border-style: solid; border-color: #ebebeb; width: 80%; height: 46px;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">80 kV &#8211; 300 kV<br data-rich-text-line-break=\"true\" \/>Alignments for 120, 200 and 300kV<\/td>\n<\/tr>\n<tr style=\"height: 70px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 70px; border-style: solid; border-color: #ebebeb; width: 20%;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">TEM magnification range<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 70px; border-style: solid; border-color: #ebebeb; width: 80%;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">Up to 195,000X with Falcon IV (0.38 \u00c5\/pixel) <br data-rich-text-line-break=\"true\" \/>165,000X with K3 detector (0.52 \u00c5\/pixel and 0.26 \u00c5\/pixel in super res mode)<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 23px; border-style: solid; border-color: #ebebeb; width: 20%;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">Ion source<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 23px; border-style: solid; border-color: #ebebeb; width: 80%;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">X-FEG<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 23px; border-style: solid; border-color: #ebebeb; width: 20%;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">Operating conditions<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 23px; border-style: solid; border-color: #ebebeb; width: 80%;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">Cryo \/ liquid nitrogen conditions<\/td>\n<\/tr>\n<tr style=\"height: 140px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 140px; border-style: solid; border-color: #ebebeb; width: 20%;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">Detector<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 140px; border-style: solid; border-color: #ebebeb; width: 80%;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">Ceta 4kx4k 16M camera<br data-rich-text-line-break=\"true\" \/>Gatan K3 camera (including energy filter BioContinuum GIF)<br data-rich-text-line-break=\"true\" \/>Falcon 4 camera<br data-rich-text-line-break=\"true\" \/>Panther segmented STEM detector<br data-rich-text-line-break=\"true\" \/>Fischione annular dark-field STEM detector<\/td>\n<\/tr>\n<tr style=\"height: 70px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 70px; border-style: solid; border-color: #ebebeb; width: 20%;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">Configuration<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 70px; border-style: solid; border-color: #ebebeb; width: 80%;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">Autoloader with up to 12 grids <br data-rich-text-line-break=\"true\" \/>Automated data acquisition at cryo-conditions <br data-rich-text-line-break=\"true\" \/>Volta phase plate<\/td>\n<\/tr>\n<tr style=\"height: 70px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 70px; border-style: solid; border-color: #ebebeb; width: 20%;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">Stage<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 70px; border-style: solid; border-color: #ebebeb; width: 80%;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">Computerized 4-axes specimen stage with \u00b170\u00b0 alpha tilt <br data-rich-text-line-break=\"true\" \/>Dual tilt cryostage<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 23px; border-style: solid; border-color: #ebebeb; width: 20%;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">Software<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 23px; border-style: solid; border-color: #ebebeb; width: 80%;\" role=\"textbox\" contenteditable=\"true\" scope=\"row\" aria-multiline=\"true\" aria-label=\"Body cell text\">TIA, EPU, Velox, SerialEM, Maps, Tomo<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The Krios G4 (Thermo-Fisher Scientific) is a 300 kV FEG cryo-electron microscope with X-FEG field emitter and a three-lens condenser system. The detector options are a Gatan BioContinuum energy filter mounted K3 direct electron detection camera and a bottom mounted Falcon 4(i) detector (FEI). Combined with fringe-free imaging (FFI) and aberration-free image shift (AFIS) in EPU, high-throughput imaging rates can be achieved. The microscope can be tuned set up for single-particle imaging, STEM and tomography experiments. Additionally, the Titan Krios is equipped with a Panther detector system (4 segments and annular dark-field detectors) that can be used for iDPC and HAADF-STEM imaging. The acquisition rate for a single particle sample on the Titan Krios is ~250-700 acquisitions\/hour and we have achieved a maximal resolution of 1.7 \u00c5 with an apo-ferritin test sample.<\/p>\n","protected":false},"author":2,"featured_media":6140,"parent":6072,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/pagebuilder.php","meta":{"_themeisle_gutenberg_block_has_review":false,"footnotes":""},"class_list":["post-6133","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/6133","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/comments?post=6133"}],"version-history":[{"count":12,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/6133\/revisions"}],"predecessor-version":[{"id":7484,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/6133\/revisions\/7484"}],"up":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/6072"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/media\/6140"}],"wp:attachment":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/media?parent=6133"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}