{"id":6110,"date":"2023-04-16T09:20:43","date_gmt":"2023-04-16T09:20:43","guid":{"rendered":"https:\/\/er-c.org\/?page_id=6110"},"modified":"2023-10-05T10:59:34","modified_gmt":"2023-10-05T10:59:34","slug":"tfs-talos-arctica-g2","status":"publish","type":"page","link":"https:\/\/er-c.org\/index.php\/facilities-2\/life-science\/cryo-electron-microscopy-facility\/cryo-em-instrumentation\/cryo-em-microscopes\/tfs-talos-arctica-g2\/","title":{"rendered":"TFS Talos Artica G2"},"content":{"rendered":"\n<h1 class=\"wp-block-heading\">TFS Talos Arctica G2  <\/h1>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"265\" data-id=\"6890\" src=\"https:\/\/er-c.org\/wp-content\/uploads\/2023\/05\/Talos-Arctica-neu-1024x265.png\" alt=\"\" class=\"wp-image-6890\" srcset=\"https:\/\/er-c.org\/wp-content\/uploads\/2023\/05\/Talos-Arctica-neu-1024x265.png 1024w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/05\/Talos-Arctica-neu-300x78.png 300w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/05\/Talos-Arctica-neu-768x199.png 768w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/05\/Talos-Arctica-neu-1536x398.png 1536w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/05\/Talos-Arctica-neu-2048x531.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<figcaption class=\"blocks-gallery-caption wp-element-caption\">A) Operator (Dr. Julio Ortiz) captured loading sample on Talos Arctica 200 kV B). Trainer and user (Dr. Saba Shahzad and Esther Hudina) screening the samples on Talos Arctica 200kV C). Micrograph of vitrified tobacco mosaic virus (TMV) as viewed at 100 kX nominal magnification in Talos Arctica 200 kV (picture credit: Dr. Olivera Korculanin)<\/figcaption><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-headline so-widget-sow-headline-default-f8d66e93cdeb\"\n\t\t\t\n\t\t><div class=\"sow-headline-container \">\n\t\t\t\t\t\t<div class=\"decoration\">\n\t\t\t\t\t\t<div class=\"decoration-inside\"><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n<\/div>\n\n\n<h2>Typical applications<\/h2>\n<p>The Talos Arctica (ThermoFisher Scientific) is a 200 kV microscope suitable for cryo-sample screening and high-resolution data acquisition. Main applications are single-particle imaging and cryo-tomography acquisitions. The Talos Arctica is equipped with a K3 Bioquantum energy filter which has power to resolve standard Apoferritin samples down to 2\u00c5 and ~200 acquisitions\/hour is the current rate of collection in counting mode.<\/p>\n\n\n<div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-headline so-widget-sow-headline-default-f8d66e93cdeb\"\n\t\t\t\n\t\t><div class=\"sow-headline-container \">\n\t\t\t\t\t\t<div class=\"decoration\">\n\t\t\t\t\t\t<div class=\"decoration-inside\"><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n<\/div>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h2>Technical specifications<\/h2>\n<table style=\"border-collapse: collapse; width: 100%; height: 442px; margin: 0px;\">\n<tbody>\n<tr style=\"height: 23px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 23px; border-style: solid; border-color: #ebebeb; width: 20%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">Operating voltage<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 23px; border-style: solid; border-color: #ebebeb; width: 80%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">200 kV<\/td>\n<\/tr>\n<tr style=\"height: 70px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 70px; border-style: solid; border-color: #ebebeb; width: 20%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">TEM magnification range<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 70px; border-style: solid; border-color: #ebebeb; width: 80%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">Up to130,000X with the K3 detector <br data-rich-text-line-break=\"true\" \/>(0.65 \u00c5\/pixel and 0.3 \u00c5\/pixel in super resolution mode)<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 23px; border-style: solid; border-color: #ebebeb; width: 20%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">Ion source<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 23px; border-style: solid; border-color: #ebebeb; width: 80%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">X-FEG (High-brightness field emission gun)<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 23px; border-style: solid; border-color: #ebebeb; width: 20%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">Operating conditions<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 23px; border-style: solid; border-color: #ebebeb; width: 80%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">Cryo \/ liquid nitrogen conditions<\/td>\n<\/tr>\n<tr style=\"height: 93px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 93px; border-style: solid; border-color: #ebebeb; width: 20%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">Detector<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 93px; border-style: solid; border-color: #ebebeb; width: 80%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">Ceta 4kx4k 16M Camera with Peltier cooled CMOS sensor<br data-rich-text-line-break=\"true\" \/>Gatan K3 direct electron detector with BioQuantum energy filter<\/td>\n<\/tr>\n<tr style=\"height: 70px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 70px; border-style: solid; border-color: #ebebeb; width: 20%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">Configuration<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 70px; border-style: solid; border-color: #ebebeb; width: 80%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">TFS Autoloader for 12 grids <br data-rich-text-line-break=\"true\" \/>Automated data acquisition at cryo conditions <br data-rich-text-line-break=\"true\" \/>Volta phase plate<\/td>\n<\/tr>\n<tr style=\"height: 70px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 70px; border-style: solid; border-color: #ebebeb; width: 20%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">Stage<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 70px; border-style: solid; border-color: #ebebeb; width: 80%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">Cryo-stage with dual tilt holder <br data-rich-text-line-break=\"true\" \/>Computerized 4-axes specimen stage with \u00b170\u00b0 alpha tilt<\/td>\n<\/tr>\n<tr style=\"height: 70px;\">\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 70px; border-style: solid; border-color: #ebebeb; width: 20%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">Software<\/td>\n<td class=\"block-editor-rich-text__editable wp-block-table__cell-content rich-text\" style=\"height: 70px; border-style: solid; border-color: #ebebeb; width: 80%;\" role=\"textbox\" contenteditable=\"true\" scope=\"col\" aria-multiline=\"true\" aria-label=\"Body cell text\">EPU, TIA, SerialEM<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Talos Arctica (ThermoFisher Scientific) is a 200 kV microscope suitable for cryo-sample screening and high-resolution data acquisition. Main applications are single-particle imaging and cryo-tomography acquisitions. The Talos Arctica is equipped with a K3 Bioquantum energy filter which has power to resolve standard Apoferritin samples down to 2\u00c5 and ~200 acquisitions\/hour is the current rate of collection in counting mode.<\/p>\n","protected":false},"author":2,"featured_media":6130,"parent":6072,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/pagebuilder.php","meta":{"_themeisle_gutenberg_block_has_review":false,"footnotes":""},"class_list":["post-6110","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/6110","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/comments?post=6110"}],"version-history":[{"count":17,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/6110\/revisions"}],"predecessor-version":[{"id":7483,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/6110\/revisions\/7483"}],"up":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/6072"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/media\/6130"}],"wp:attachment":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/media?parent=6110"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}