{"id":1230,"date":"2021-03-17T08:35:36","date_gmt":"2021-03-17T08:35:36","guid":{"rendered":"https:\/\/er-c.org\/?page_id=1230"},"modified":"2023-08-02T14:27:01","modified_gmt":"2023-08-02T14:27:01","slug":"fei-titan-80-300-tem","status":"publish","type":"page","link":"https:\/\/er-c.org\/index.php\/facilities-2\/facilities-material-science\/material-science\/fei-titan-80-300-tem\/","title":{"rendered":"FEI Titan 80-300 TEM"},"content":{"rendered":"\n<h1 class=\"wp-block-heading\">FEI Titan 80-300 TEM<\/h1>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile is-vertically-aligned-top\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"683\" height=\"1024\" src=\"https:\/\/er-c.org\/wp-content\/uploads\/2023\/07\/titan_t_er_c_1_01-683x1024.jpg\" alt=\"\" class=\"wp-image-7148 size-full\" srcset=\"https:\/\/er-c.org\/wp-content\/uploads\/2023\/07\/titan_t_er_c_1_01-683x1024.jpg 683w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/07\/titan_t_er_c_1_01-200x300.jpg 200w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/07\/titan_t_er_c_1_01-768x1151.jpg 768w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/07\/titan_t_er_c_1_01-1025x1536.jpg 1025w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/07\/titan_t_er_c_1_01-1366x2048.jpg 1366w, https:\/\/er-c.org\/wp-content\/uploads\/2023\/07\/titan_t_er_c_1_01-scaled.jpg 1708w\" sizes=\"auto, (max-width: 683px) 100vw, 683px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>The FEI Titan 80-300 TEM is a high-resolution transmission electron microscope equipped with a field emission gun and a corrector for the spherical aberration (<em>C<\/em><sub>S<\/sub>) of the imaging lens system. The instrument is designed for the investigation of a wide range of solid state phenomena taking place on the atomic scale, which requires true atomic resolution capabilities. Under optimum optical settings of the image <em>C<\/em><sub>S<\/sub>-corrector (CEOS CETCOR) the point-resolution is extended up to the information limit of well below 100 pm with 200 keV and 300 keV electrons. A special piezo-stage design allows ultra-precise positioning of the specimen in all 3 dimensions. Digital images are acquired with a Gatan 2k x 2k slow-scan charged coupled device camera.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Typical Applications and Limitations of Use<\/h2>\n\n\n\n<p>The configuration of the FEI Titan 80-300 TEM is dedicated to provide optimum performance for high-resolution transmission electron microscopy imaging techniques to be applied to solid state materials. The typical setup used for high-resolution transmission electron microscopy (HRTEM) imaging involves an intentional over-compensation of the intrinsically positive spherical aberration of the objective lens towards a total negative spherical aberration of the imaging system. The negative spherical-aberration imaging (NCSI) technique provides maximum contrast transfer up to the information limit of the instrument yielding bright-atom contrast. The NCSI technique enables on the one hand a more intuitive interpretation of HRTEM images in terms of direct structure projections of e.g. structural defects and interfaces. On the other hand, the superior image contrast at minimum delocalisation allows one to quantify individual atomic displacements with picometre precision from a single image to study for example local electric polarisation phenomena. A further technique applied with this instrument is the reconstruction of the electron wave function based on a focal series of HRTEM images, which allows one to eliminate nonlinear contrast artifacts and residual imaging aberrations from the experimental data.<\/p>\n\n\n\n<p>The FEI Titan 80-300 TEM is not intended for the investigation of aqueous, contaminated, ferromagnetic or organic samples without further discussions with both of the instruments officers and the ER-C general management.<\/p>\n<\/div><\/div>\n\n\n\n<h2>Sample Environment<\/h2>\n<p>Apart from the special case of the utilisation of dedicated cooling or heating stages, the FEI Titan 80-300 TEM will allow samples to be investigated either under room temperature or liquid nitrogen cooling conditions at a vacuum level of about 10<sup>\u20138<\/sup> mbar. Besides this standard setup, the sample environment can be adapted to various conditions, e.g. the thermal treatment or the application of external electric or magnetic fields to samples, making use of a wide portfolio of <em>in situ<\/em> TEM holders available through the ER-C user services.<\/p>\n\n\n<div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-headline so-widget-sow-headline-default-48bb96655c8e\"\n\t\t\t\n\t\t><div class=\"sow-headline-container \">\n\t\t\t\t\t\t<div class=\"decoration\">\n\t\t\t\t\t\t<div class=\"decoration-inside\"><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n<\/div>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2>Technical Specifications<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Electron acceleration voltage<\/td><td>80, 200, and 300 kV<\/td><\/tr><tr><td>Information limit (TEM) @ 300 kV<\/td><td>&lt; 90 pm<\/td><\/tr><tr><td>Information limit (TEM) @ 200 kV<\/td><td>&lt; 100 pm<\/td><\/tr><tr><td>Information limit (TEM) @ 80 kV<\/td><td>&lt; 200 pm<\/td><\/tr><tr><td>Total system drift (TEM)<\/td><td>&lt; 300 pm min<sup>-1<\/sup> (rms)<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2>Specimen Stages<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Piezo stage extension for ultra-precise sample positioning and linear drift compensation<\/td><td>&nbsp;<\/td><\/tr><tr><td>Double tilt low background holder<\/td><td>\u00b1 40 \u00b0<\/td><\/tr><tr><td>High field of view single tilt holder<\/td><td>\u00b1 50 \u00b0<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2>Detectors<\/h2>\n\n\n\n<div id=\"wp-block-themeisle-blocks-icon-list-04518c93\" class=\"wp-block-themeisle-blocks-icon-list\">\n<div id=\"wp-block-themeisle-blocks-icon-list-item-2f700338\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-bullseye wp-block-themeisle-blocks-icon-list-item-icon\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content\">Peltier cooled Ultrascan 1000P charge coupled device camera (CCD) with a readout speed of 4 M pixel sec<sup>-1<\/sup> and a format of 2048 x 2048 pixels of 14 microns in size. (Gatan)<\/p><\/div>\n<\/div>\n\n\n<div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-headline so-widget-sow-headline-default-48bb96655c8e\"\n\t\t\t\n\t\t><div class=\"sow-headline-container \">\n\t\t\t\t\t\t<div class=\"decoration\">\n\t\t\t\t\t\t<div class=\"decoration-inside\"><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n<\/div>\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2>Instrument Related Publications<\/h2>\n\n\n\n<div id=\"wp-block-themeisle-blocks-icon-list-632f0de5\" class=\"wp-block-themeisle-blocks-icon-list\">\n<div id=\"wp-block-themeisle-blocks-icon-list-item-54da7506\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-long-arrow-alt-right wp-block-themeisle-blocks-icon-list-item-icon\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content\">Barthel J and Thust A (2008). Quanti\ufb01cation of the Information Limit of Transmission Electron Microscopes. Phys. Rev. Lett. 101 (2008) 200801. doi 10.1103\/PhysRevLett.101.200801.<\/p><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-icon-list-item-ac1cd7f7\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-long-arrow-alt-right wp-block-themeisle-blocks-icon-list-item-icon\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content\">Jia CL et al. (2010). On the bene\ufb01t of the negative-spherical-aberration imaging technique for quantitative HRTEM. Ultramicroscopy 110 (2010) 500-505. doi 10.1016\/j.ultramic.2009.10.006.<\/p><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-icon-list-item-54fb0ba7\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-long-arrow-alt-right wp-block-themeisle-blocks-icon-list-item-icon\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content\">Barthel J and Thust A (2010). Aberration measurement in HRTEM: Implementation and diagnostic use of numerical procedures for the highly precise recognition of diffractogram patterns. Ultramicroscopy 111 (2010) 27\u201346. doi 10.1016\/j.ultramic.2010.09.007.<\/p><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-icon-list-item-d48aed4a\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-long-arrow-alt-right wp-block-themeisle-blocks-icon-list-item-icon\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content\">Barthel J and Thust A (2013). On the optical stability of high-resolution transmission electron microscopes. Ultramicroscopy 134 (2013) 6\u201317. doi 10.1016\/j.ultramic.2013.05.001.<\/p><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-icon-list-item-8e3a223f\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-long-arrow-alt-right wp-block-themeisle-blocks-icon-list-item-icon\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content\">Jia CL et al. (2014). Determination of the 3D shape of a nanoscale crystal with atomic resolution from a single image. Nature Materials 13 (2014) 1044-1049. doi 10.1038\/nmat4087<\/p><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-icon-list-item-58c61f4f\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-long-arrow-alt-right wp-block-themeisle-blocks-icon-list-item-icon\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content\">Thust A et al. (1996). Focal-series reconstruction in HRTEM: simulation studies on non-periodic objects. Ultramicroscopy 64 (1996) 211-230. doi:10.1016\/0304-3991(96)00022-8.<\/p><\/div>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Cs-corrected high-resolution transmission electron microscope equipped with a piezo-stage for ultra-precise 3D specimen positioning and an information limit well below 100 pm&#8230;<\/p>\n","protected":false},"author":3,"featured_media":7149,"parent":6019,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/pagebuilder.php","meta":{"_themeisle_gutenberg_block_has_review":false,"footnotes":""},"class_list":["post-1230","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/1230","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/comments?post=1230"}],"version-history":[{"count":29,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/1230\/revisions"}],"predecessor-version":[{"id":7281,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/1230\/revisions\/7281"}],"up":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/pages\/6019"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/media\/7149"}],"wp:attachment":[{"href":"https:\/\/er-c.org\/index.php\/wp-json\/wp\/v2\/media?parent=1230"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}